Ru En
Designer and manufacturer of communication equipment
Russia (GMT +7)

Data center switch MES5400-48

Mass production
Key features
  • High performance (up to 2.16 Тbps)
  • Non-blocking architecture
  • L3 switches
  • Stacking up to 8 devices
  • Power supply redundancy
  • Front-to-Back cooling
  • Dual ventilation system
MES5310-48, MES5400-24 and MES5400-48 switches are high performance devices with 40GBASE-R and 100GBASE-R interfaces that can be used as aggregation switches in carrier networks and as Top-of-Rack or End-of-Row switches for datacenters. 

The switch ports support speed of 1 Gbps (SFP), 10 Gbps (SFP+),40 Gbps (QSFP+), and 100 Gbps (QSFP28). HG interface split mode supports speed of 1 Gbps, 10 Gbps, and 25 Gbps. Split mode allows to split up to 6 HG interfaces for a total of 24 TWE interfaces.

The non-blocking architecture guarantees lossless packet forwarding at wire speed with minimum and predictable delays for all types of traffic.

The front-to-back cooling provides effective cooldown in modern data centers.

The redundant and hot-swappable fans and AC/DC power supplies along with advanced hardware monitoring functions provide high reliability and uninterrupted services.The devices support EVPN/VXLAN technology to create networks with simple, high-performance and scalable data center architecture.
Specifications
Modules and additional devices
Documents and files
Warranty
Interfaces
  • 10/100/1000BASE-T (OOB) - 1
  • 1000BASE-X (SFP)/10GBASE-R (SFP+) - 48
  • 40GBASE-R (QSFP+)/100GBASE-R (QSFP28) - 6
  • USB 2.0 - 1
  • Console port RS-232 (RJ-45) - 1
Performance
  • Bandwidth - 2.16 Tbps
  • Throughput for 64 bytes1 - 1041.5 MPPS
  • Buffer memory - 12 MB
  • RAM (DDR4) - 8 GB
  • ROM (embedded uSSD) - 8 GB
  • MAC table - 262144
  • ARP table2 - 131063
  • VLAN table - 4094
  • L2 Multicast groups - 4092
  • SQinQ rules - 1320 (ingress), 1320 (egress)
  • MAC ACL rules - 10737
  • IPv4/IPv6 ACL rules - 10737/5367
  • L3 IPv4 Unicast routes3 - 32669
  • L3 IPv6 Unicast routes3 - 8165
  • L3 IPv4 Multicast routes3 - 16324
  • L3 IPv6 Multicast routes3 - 4079
  • VRRP routers - 127
  • Maximum size of ECMP groups - 64
  • VRF number - 251 (including default VRF)
  • L3 interfaces - 2050
  • Maximum number of VXLAN - 4093
  • Link Aggregation Groups (LAG) - 128, up to 8 ports in one LAG
  • Quality of Service (QoS) - 8 egress queues per port
  • Jumbo frames - 10240 bytes
  • Stacking - up to 8 devices
Interface features
  • Head-of-line blocking (HOL) protection
  • Back Pressure
  • Auto MDI/MDIX
  • Jumbo Frames
  • Flow Control (IEEE 802.3X)
  • Port Mirroring
MAC table features
  • Independent learning mode per VLAN
  • MAC Multicast Support
  • Configurable MAC address aging time
  • Static MAC Entries
  • MAC Flapping logging
VLAN features
  • Voice VLAN
  • IEEE 802.1Q
  • Q-in-Q
  • Selective Q-in-Q
  • GVRP
L2 Multicast functions
  • Multicast profiles
  • Static Multicast groups
  • IGMP Snooping v1,2,3
  • Port/host-based IGMP Snooping Fast Leave
  • PIM-Snooping
  • IGMP authorization via RADIUS
  • MLD Snooping v1,2
  • IGMP Querier
L2 functions
  • STP (Spanning Tree Protocol, IEEE 802.1d)
  • RSTP (Rapid Spanning Tree Protocol, IEEE 802.1w)
  • MSTP (Multiple Spanning Tree Protocol, IEEE 802.1s)
  • Spanning Tree Fast Link option
  • STP Root Guard
  • BPDU Filtering
  • STP BPDU Guard
  • Loopback Detection (LBD)
  • ERPS (G.8032v2)
  • Flex-link
  • PVSTP+
  • RPVSTP+
L3 functions
  • Static routing
  • Dynamic routing protocols RIPv2, OSPFv2, OSPFv3, BGP1(IPv4 Unicast, IPv4 Multicast), IS-IS
  • Address Resolution Protocol (ARP)
  • VRRP
  • PIM SM, PIM DM, IGMP Proxy, MSDP
  • BFD
  • IP Unnumbered
  • VRF lite
EVPN/VXLAN5
  • L2VPN 
  • L3VPN 
Link Aggregation functions
  • Link Aggregation Groups (LAG)
  • LACP
  • LAG Balancing Algorithm
  • Multi-Switch Link Aggregation Group (MLAG)
IPv6 support
  • IРv6 Host
  • Dual stack IРv6, IРv4
Service functions
  • Optical transceiver diagnostics
  • Green Ethernet
Security functions
  • DHCP Snooping
  • DHCP Option 82
  • IP Source Guard
  • Dynamic ARP Inspection
  • sFlow
  • MAC-based authentication, MAC address limitation, static MAC entries
  • Port-based authentication IEEE 802.1x
  • Guest VLAN
  • DoS attack prevention
  • Traffic segmentation
  • DHCP clients filtering
  • BPDU attack prevention
  • NetBIOS/NetBEUI filtering
Access Control Lists (ACL)
  • L2-L3-L4 ACL  (Access Control List)
  • Time-Based ACL
  • IРv6 ACL
  • ACL based on:
    • Physical port number
    • IEEE 802.1p
    • VLAN ID
    • EtherType
    • DSCP
    • Protocol type
    • TCP/UDP port number
Management functions
  • Configuration and firmware download and upload via TFTP/SCP
  • SNMP
  • Command Line Interface (CLI)
  • Web interface
  • Syslog
  • SNTP (Simple Network Time Protocol)
  • Traceroute
  • LLDP (802.1ab) + LLDP MED
  • Access control – privilege levels
  • Management ACL
  • Management interface blocking
  • Local authentication
  • IP addresses filtering for SNMP
  • RADIUS/TACACS+ (Terminal Access Controller Access Control System) client
  • SSH server
  • Telnet server
  • SSL
  • Macrocommands
  • CLI command logging
  • System log
  • DHCP auto provisioning
  • DHCP Relay (Option 82)
  • DHCP Option 12
  • DHCP server
  • Debugging commands
  • Rate limit of traffic to CPU
  • Password encryption
  • Password recovery
  • Ping (IPv4/IPv6)
Monitoring functions
  • Interface statistics
  • RMON/SMON
  • Task and traffic type-based CPU utilization monitoring
  • Temperature monitoring
  • TCAM monitoring
  • IPFIX
Quality of Service (QoS) and rate limiting
  • QoS statistics
  • Shaping, Policing
  • IEEE 802.1р Class of Service (CoS)
  • Broadcast Storm Control
  • Bandwidth management
  • Strict Priority/Weighted Round Robin (WRR) scheduling algorithms
  • Three marking colors
  • ACL-based CoS/DSCP metric assignment
  • ACL-based VLAN metric assignment
  • Setting the IEEE 802.1p priority for management VLAN
  • DSCP to CoS, CoS to DSCP remarking
  • 802.1p DSCP mark assignment for IGMP protocol
OAM
  • 802.3ah Ethernet Link OAM
  • 802.3ah Unidirectional Link Detection
MIB
  • RFC 1065, 1066, 1155, 1156, 2578 MIB Structure
  • RFC 1212 Concise MIB Definitions
  • RFC 1213 MIB II
  • RFC 1215 MIB Traps Convention
  • RFC 1493, 4188 Bridge MIB
  • RFC 1157, 2571-2576 SNMP MIB
  • RFC 1901-1908, 3418, 3636, 1442, 2578 SNMPv2 MIB
  • RFC 1271, 1757, 2819 RMON MIB
  • RFC 2465 IPv6 MIB
  • RFC 2466 ICMPv6 MIB
  • RFC 2737 Entity MIB
  • RFC 4293 IPv6 SNMP Mgmt Interface MIB
  • Private MIB
  • RFC 3289 DIFFSERV MIB
  • RFC 2021 RMONv2 MIB
  • RFC 1398, 1643, 1650, 2358, 2665, 3635 Ether-like MIB
  • RFC 2668 IEEE 802.3 MAU MIB
  • RFC 2674, 4363 IEEE 802.1p MIB
  • RFC 2233, 2863 IF MIB
  • RFC 2618 RADIUS Authentication Client MIB
  • RFC 4022 MIB for TCP
  • RFC 4113 MIB for UDP
  • RFC 3298 MIB for Diffserv
  • RFC 2620 RADIUS Accounting Client MIB
  • RFC 2925 Ping & Traceroute MIB
  • RFC 768 UDP
  • RFC 791 IP
  • RFC 792 ICMPv4
  • RFC 2463, 4443 ICMPv6
  • RFC 4884 Extended ICMP to support Multi-Part messages
  • RFC 793 TCP
  • RFC 2474, 3260 Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 headers
  • RFC 1321, 2284, 2865, 3580, 3748 Extensible Authentication Protocol (EAP)
  • RFC 2571-2574 SNMP
  • RFC 826 ARP
  • IEC 61850
Physical parameters

 

 

Power supply

AC: 176–264 V, 50–60 Hz 

DC: 36–72 V

Power supply options:

one AC/DC power supply

two AC/DC hot-swappable power supplies

Input current

0.5–1.0 A for AC

2–4.5 A for DC

Maximum power consumption

170 W

Heat dissipation

170 W

Dying Gasp support

no

Operating temperature

from 0 to +45 °С

Storage temperature

from -50 to +70 °С

Operating humidity

no more than 80 %

Cooling

Front-to-Back, 4 fans

Dimensions (W × H × D)

440 × 44 × 447 mm

Weight

8.7 kg



1 Values are given for one-way transmission.
2 For each host in the ARP table, an additional entry is created in switching table. The number of ARP with EVPN license installed for MES5400-24 is 30711 and for MES5400-48 is 129015
3 IPv4/IPv6 Unicast/Multicast routes share hardware resources.
4 BGP protocol support is provided under the license
5 EVPN support is provided under the license

Additional modules (doesn't included in basic package)

PM350-48/12

PM350-48/12 power module, 35-75V DC, 350W

РМ350-220/12

РМ350-220/12 power module, 176-264V AC, 350W

1 fiber

Part Number

 SFP 1.25 GE module, 3 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS3 / FH-SB5312CDS3

 SFP 1.25 GE module, 3 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL3 / FH-SB5312CDL3

 SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS20 / FH-SB5312CDS20

SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL20 / FH-SB5312CDL20

SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM, INDUSTRIAL

FH-SB3512IDS20 / FH-SB5312IDS20

SFP 1.25 GE module 40 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL40 / FH-SB5312CDL40

SFP 1.25 GE module 40 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS40 / FH-SB5312CDS40

SFP 1.25 GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL80 / FH-SB5412CDL80

SFP 1.25 GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 SC set, DDM

FH-SB4512CDS80 / FH-SB5412CDS80

SFP 1.25 GE module 120 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL120 / FH-SB5412CDL120

SFP 1.25 GE module 120 km, SM, 1 fiber, TX/RX 1490/1550 SC set, DDM

FH-SB4512CDS120 / FH-SB5412CDS120

SFP 1.25 GE module 160 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL160 / FH-SB5412CDL160

 2 fibers

 

SFP 1.25 GE module 550 m, MM, 2 fibers, 850 nm,  LC,  DDM

FH-S8512CDL05

SFP 1.25 GE module 2 km, ММ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL2

SFP 1.25 GE module 20 km, SМ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL20

SFP 1.25 GE module 40 km, SМ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL40

SFP 1.25 GE module 80 km, SМ, 2 fibers, 1550 nm, LC, DDM

FH-S5512CDL80

SFP 1.25 GE module 120 km, SМ, 2 fibers, 1550 nm, LC, DDM

FH-S5512CDL120

SFP 1.25 GE module 160 km, SМ, 2 fibers, 1550 nm, LC, DDM   

FH-S5512CDL160

SFP+

 

 1 fiber

 

SFP+ 10GE module 3 km, SM, 1 fiber, TX/RX 1290/1310 LC set, DDM

FH-SPB311TCDL3 / FH-SPB191TCDL3

SFP+ 10GE module 20 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL20 / FH-SPB321TCDL20

SFP+ 10GE module 40 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL40 / FH-SPB321TCDL40

SFP+ 10GE module 60 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL60 / FH-SPB321TCDL60

SFP+ 10GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SPB451TCDL80 / FH-SPB541TCDL80

SFP+ 10GE module 100 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SPB451TCDL100 / FH-SPB541TCDL100

 2 fibers

 

SFP+ 10GE module, 0.3 km, MM, 2 fibers, 850 nm, LC, DDM

FH-SP851TCDL03

SFP+ 10GE module, 20 km, SM, 2 fibers, 1310 nm, LC, DDM

FH-SP311TCDL20

SFP+ 10GE module, 40 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL40

SFP+ 10GE module, 80 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL80

SFP+ 10GE module, 100 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL100

SFP/SFP+ transceivers with RJ-45 interface

 

SFP transceiver of 10/100/1000 BASE-T 

FH-ST2

SFP+ transceiver of 10GBASE-Т 

FH-10SFP-T

SFP+ Direct Attach Cable 

 

SFP+ Direct attach cable, 10G, 1m

FH-DP1T30SS01

SFP+ Direct attach cable, 10G, 2m

FH-DP1T30SS02

SFP+ Direct attach cable, 10G, 3m

FH-DP1T30SS03

SFP+ Direct attach cable, 10G, 5m

FH-DP1T30SS05

QSFP Direct Attach Cable 

 

QSFP Direct attach active cable, 1m

FH-DA4T26QQ01

QSFP Direct attach passive cable, 1m

FH-DP4T30QQ01

QSFP+ to 4хSFP+ Direct attach passive cable, 1m

FH-DP4T30QS01

QSFP+ to QSFP+ AOC Cable active 7m  

FH-A40M2QQ07

 QSFP

 

QSFP+ 40G ММ 100M

FH-QSFP4TCDM01

MPO CABLE patch cord UPC/UPC 2m Female (для QSFP+ 40G 100M)

NS-MPO12-MPO12-A3

QSFP+ 40G module, 10 km, SM, 1 fiber, 1270 nm/1290 nm/1310 nm/1330 nm,  LC,  DDM

FH-QSFP4TCDL10


Operational lifetime of the ELTEX equipment
In development
1
Pre-production
2
Mass production
3
Mass production is over
4
Sold out
5
Support is over
6
Regardless of the operational lifetime stage, Eltex provides a 12 months warranty on all its telecommunication equipment.
During the warranty period the manufacturer ensures technical support and free-of-charge repair at the Enterprise which is situated in Novosibirsk.
As part of the warranty service, technical support is provided on the first-in first-out principle.
The priority support packages of 8/5 and 27/7 types are subjects to additional charges.

Помогите сделать