Ethernet Access Switch MES2420B-24D

Mass production
  • Bandwidth up to 200 Gbps
  • Up to 24 ports of 2.5GBASE-T
  • Advanced L2 features
  • L3 switches
  • Support for Multicast (IGMP Snooping, MVR)
  • Advanced security functions (L2-L4 ACL, IP Source Guard, Dynamic ARP Inspection and etc.)
MES2420 series switches provide end users connection to networks of large enterprises, small and mid-sized businesses and service providers via 2.5G/10G interfaces.

Uninterruptible power
MES2420B-24D switches can be equipped with a rechargeable battery to ensure power supply in case of the 230 V primary power supply loss. The switches are equipped with a power supply unit which allows the battery to be charged when 230 V power is available. Power supply redundancy system makes it possible to monitor the state of the primary network and notify of a power type switching.
Specifications
Documents and files
Warranty
Interfaces
  • 10/100/1000/2500BASE-T (RJ-45) - 24
  • 1000BASE-X (SFP)/10GBASE-R (SFP+) - 4
  • Console port RS-232 (RJ-45) - 1
Performance
  • Bandwidth - 200 Gbps
  • Throughput for 64-byte packets - 148.8 MPPS
  • Buffer memory - 2 MB
  • RAM (DDR3) - 1 GB
  • ROM (SPI Flash) - 64 MB
  • MAC table - 32768
  • ARP table - 1000
  • VLAN table - 4094
  • L2 Multicast groups (IGMP Snooping) - 4093
  • L3 Multicast groups (IGMP proxy) - 2048
  • SQinQ rules - 768 (ingress)/1024(egress)
  • MAC ACL rules - 766
  • IPv4/IPv6 ACL rules - 640/320
  • L3 IPv4 Unicast routes - 1957
  • L3 IPv6 Unicast routes - 21
  • VRRP routers - 32
  • L3 interfaces - 8 VLANs, up to 5 IPv4 addresses per VLAN, up to 22 IРv6 GUAs for all VLANs in summary
  • Link Aggregation Groups (LAG) - 24 groups, up to 8 ports in one LAG
  • Quality of Service (QoS) - 8 egress queues per port
  • Jumbo frames - maximum packet size is 12288 bytes
Interface features
  • Head-of-line blocking (HOL) protection
  • Auto MDI/MDIX
  • Jumbo frames
  • Flow control (IEEE 802.3X)
  • Port mirroring (SPAN, RSPAN)
МAC table
  • Independent learning mode per VLAN
  • MAC Multicast Support
  • Configurable aging time of MAC addresses
  • Static MAC Entries
  • MAC change events monitoring per ports
  • MAC Flapping
VLAN features
  • Voice VLAN
  • IEEE 802.1Q
  • Q-in-Q
  • Selective Q-in-Q
  • GVRP
  • MAC-based VLAN
  • Protocol-based VLAN
L2 Multicast features
  • Multicast profiles
  • Static Multicast groups
  • IGMP Snooping v1,2,3
  • IGMP Snooping fast-leave
  • IGMP proxy-report
  • IGMP authorization via RADIUS
  • IGMP Querier
  • MVR
L2 features
  • STP (Spanning Tree Protocol, IEEE 802.1d)
  • RSTP (Rapid Spanning Tree Protocol, IEEE 802.1w)
  • MSTP (Multiple Spanning Tree Protocol, IEEE 802.1s)
  • STP Root Guard
  • STP Loop Guard
  • STP BPDU Guard
  • BPDU Filtering
  • Spanning Tree Fast Link option
  • Layer 2 Protocol Tunneling (L2PT)
  • Loopback Detection (LBD)
  • Port isolation
  • Storm Control for different traffic types (broadcast, multicast, unknown unicast)
  • ERPS (G.8032v2)
L3 Multicast features
  • IGMP proxy (RFC 4605)
  • IGMP proxy fast-leave
L3 features
  • Static IPv4, IPv6 routes
  • Dynamic routing protocols RIPv1/2, OSPFv2/3
  • VRRP protocol
Link Aggregation functions
  • Static LAG
  • Dynamic LAG (LACP)
  • LAG Balancing Algorithm
Service functions
  • Virtual Cable Testing (VCT)
  • Optical Transceiver Diagnostics
IРv6
  • IPv6 Host
  • IPv4, IРv6 dual stack
Security functions
  • DHCP Snooping
  • DHCP Option 82
  • IP Source Guard
  • Dynamic ARP Inspection (Protection)
  • MAC-based authentication, Port Security, Static MAC entries
  • Port-based authentication IEEE 802.1x
  • Guest VLAN
  • DoS attacks prevention
  • Traffic segmentation
  • DHCP clients filtering
  • BPDU attacks prevention
  • PPPoE Intermediate agent
  • DHCPv6 Snooping
  • IPv6 Source Guard
  • IPv6 ND Inspection
  • IPv6 RA Guard
ACL (Access Control Lists)
  • L2-L3-L4 ACL (Access Control List)
  • IPv6 ACL
  • ACL based on:
    • Switch port
    • IEEE 802.1p priority
    • VLAN ID
    • EtherType
    • DSCP
    • IP protocol type
    • TCP/UDP port number
    • User Defined Bytes
Quality of Service (QoS) and rate limiting
  • Port rate limiting (shaping, policing)
  • IEEE 802.1p Class of Service (CoS)
  • Queue scheduling algorithms: Strict Priority/Weighted Round Robin (WRR)
  • ACL-based traffic classification
  • ACL-based CoS/DSCP mark assignment
  • CoS to DSCP remarking
  • DSCP to CoS remarking
  • ACL-based VLAN assignment
ОАМ
  • IEEE 802.3ah, Ethernet OAM
  • IEEE 802.3ah Unidirectional Link Detection (UDLD)
Main management functions
  • Download and upload of configuration file via TFTP/SFTP
  • Automated backup of configuration file via TFTP/SFTP
  • Simple Network Management Protocol (SNMP)
  • Command Line Interface (CLI)
  • Web interface
  • Syslog
  • SNTP (Simple Network Time Protocol)
  • Traceroute
  • LLDP (IEEE 802.1ab) + LLDP MED
  • Processing of management traffic with two IEEE 802.1Q headers
  • Authorization of entered commands using TACACS+ server
  • IPv4/IPv6 ACL support for device management
  • Switch access management — privilege levels for users
  • Management interface blocking
  • Local authentication
  • IP addresses filtering for SNMP
  • RADIUS, TACACS+ (Terminal Access Controller Access Control System) clients
  • SSH, Telnet client
  • Telnet, SSH server
  • Macrocommands
  • Input commands logging via TACACS+
  • DHCP autoprovision
  • DHCP Relay (IРv4 support)
  • DHCP Relay Option 82
  • DHCP server
  • PPPoE Circuit-ID tag
  • Flash File System
  • Debug commands
  • CPU traffic limiting
  • Password encryption
  • Ping (IPv4/IPv6 support)
  • IPv4/IPv6 static routes support
  • Support for multiple versions of configuration file
Monitoring functions
  • Interface statistics
  • CPU utilization monitoring per task and per queue
  • RAM usage monitoring
  • Temperature monitoring
  • TCAM monitoring
Uninterruptible power supply
  • Automatic switching to 12 V rechargeable battery when the primary power supply (230 V) fails, and vice versa
  • 12 V battery charging when operating from 230 V primary power supply
  • Power supply type monitoring (SNMP)
  • Notification of switching from one type of power to another
  • Battery connection indication
  • Low battery alarm
  • Short circuit protection
MIB/IETF
  • RFC 1065, 1066, 1155, 1156, 2578 MIB Structure
  • RFC 1212 Concise MIB Definitions
  • RFC 1213 MIB II
  • RFC 1215 MIB Traps Convention
  • RFC 1493, 4188 Bridge MIB
  • RFC 1157, 2571-2576 SNMP MIB
  • RFC 1901-1908, 3418, 3636, 1442, 2578 SNMPv2 MIB
  • RFC 2465 IPv6 MIB
  • RFC 2737 Entity MIB
  • RFC 4293 IPv6 SNMP Mgmt Interface MIB
  • Private MIB
  • RFC 1398, 1643, 1650, 2358, 2665, 3635 Ether-like MIB
  • RFC 2668 802.3 MAU MIB
  • RFC 2674, 4363 802.1p MIB
  • RFC 2233, 2863 IF MIB
  • RFC 2618 RADIUS Authentication Client MIB
  • RFC 4022 MIB для TCP
  • RFC 4113 MIB для UDP
  • RFC 3289 MIB для Diffserv
  • RFC 2620 RADIUS Accounting Client MIB
  • RFC 768 UDP
  • RFC 791 IP
  • RFC 792 ICMPv4
  • RFC 2463, 4443 ICMPv6
  • RFC 793 TCP
  • RFC 2474, 3260 Definition of the DS field in the IPv4 and IPv6 Headers
  • RFC 1321, 2284, 2865, 3580, 3748 Extensible Authentication Protocol (EAP)
  • RFC 2571, RFC 2572, RFC 2573, RFC 2574 SNMP
  • RFC 826 ARP
  • RFC 854 Telnet
  • IEC 61850
Physical specifications and environmental parameters
  • Power supply
    • 100–240 V AC, 50–60 Hz;
    • 12 V DC
  • Maximum power consumption - 60 W
  • Maximum power consumption (without battery charge) - 45 W
  • Heat dissipation - 48 W
  • Hardware support for Dying Gasp
  • Operating temperature - from -15 to +50 °С
  • Storage temperature - from -40 to +70 °С
  • Cooling - 2 fans
  • Operating humidity no more than 80 %
  • Form factor - 19", 1U
  • Dimensions (W × H × D) - 430 × 44 × 225 mm
  • Weight - 3.16 kg
Operational lifetime of the ELTEX equipment
In development
1
Pre-production
2
Mass production
3
Mass production is over
4
Sold out
5
Support is over
6
Regardless of the operational lifetime stage, Eltex provides a 12 months warranty on all its telecommunication equipment.
During the warranty period the manufacturer ensures technical support and free-of-charge repair at the Enterprise which is situated in Novosibirsk.
As part of the warranty service, technical support is provided on the first-in first-out principle.
The priority support packages of 8/5 and 27/7 types are subjects to additional charges.