Ethernet Access Switch MES2300B-48
- Level:
- L3
- Bandwidth:
- 176 Gbps
- Interfaces:
- 48x1G, 4x10G SFP+
- Power supply:
- AC/DC


Description
The new generation of access switches MES2300B-48 connects end users to the network of large enterprises, small and medium businesses and telecommunications operator networks using 1G/10G.
The switch functionality provides physical stacking, support for VLANs, multicast groups and advanced security features.
The MES2300B-48 switch has the ability to connect a rechargeable battery supply to ensure guaranteed power supply in case of 230 V primary power network failure. The switch is equipped with a power module that allows charging the battery when 230 V is available. The backup power system makes it possible to monitor the state of the primary network and notify of a power type switching.
Specifications
- Level:
- L3
- Bandwidth:
- 176 Gbps
- Interfaces:
- 48x1G, 4x10G SFP+
- ARP:
- 2039
- MAC table:
- 16384
- VLAN table:
- 4094
- Stacking:
- up to 8 devices
- QoS:
- 8 egress queues per port
- Power supply:
- AC/DC

Related products






Documents and files
Firmware version 6.6.7.5
Added:
- Added information about the hardware version of the device to the output of the show system id command;
- The possibility of adding VLANs on LAG interfaces via the WEB has been implemented;
- Added support for LACP Force operation mode;
- Added the display of static multicast records in the ip igmp snooping table;
- Added support for collaboration between DHCP relay and DHCP server;
- Added the ability to disable the USB port;
- Added the ability to statically configure OSPF neighbors;
- Added OSPF network type non-broadcast, point-to-multipoint non-broadcast;
- Added VRF support in DHCP Relay;
- Added support for TCP adjust-mss;
- Added the possibility of extended IS-IS database output;
- The collaboration of DHCP Relay with EVPN/VXLAN is supported;
- Added Multi-VRF support for hardware BFD sessions;
- Added the ability for VPC peer detection to work in VRF;
- Added synchronization of ARP records between switches of the same EVPN multihoming ESI group.
Fixed:
- Fixed reboot when copying configuration via scp/tftp/flash;
- Optimized work with flash memory;
- Fixed a reboot when entering the show logging command in the stack;
- Fixed a bug that causes stack units to reboot when there is a high CPU load;
- Fixed a bug that caused the stack of MES3300-48 and MES3300-48F devices to fail;
- The do show ip interface vrf all command has been restored;
- Fixed the issue of LAG LACP recovery in timeout short mode;
- Fixed an erroneous change of the OSPF zone in the settings when executing the passive-interface command;
- Fixed mac address authorization in multi-sessions mode;
- Fixed an error when copying a configuration containing the switchport trunk allowed vlan all command;
- Fixed an error in displaying the role of neighbors in the output of the show ip ospf neighbor command;
- Fixed the problem of interrupting traffic processing on the master's CPU when there is a high load on the stack;
- Fixed a problem with VXLAN traffic transmission when using trunk ports between spine/leaf;
- Fixed a problem with traffic routing via L3VNI VXLAN when there is a default route;
- Fixed the error of removing standard ipv4/ipv6 ACLs from the configuration;
- Fixed the possibility of restarting the device at the time of removing the ACL from the VLAN interface with qos advanced-mode trust dscp configured;
- Fixed a problem with blocking traffic on slave units when configuring BPDU Guard in RPVST mode;
- Fixed an issue with an i2c bus failure in the stack;
- Fixed an issue with resetting the exp label in the mpls header in transit traffic;
- Fixed a bug with MAC Flapping in the VPC scheme when using the Po interface, number above 48;
- Fixed critical errors that occur when editing device configurations in a VPC pair;
- Fixed an error with rebooting the switch during SNMP requests for DDM information;
- Fixed an error with switching to local command authorization when there is no response from the tacacs server;
- Fixed an error with authorization of commands on the backup tacacs+ server when the main server is unavailable;
- Fixed an error with rebooting the switch when authenticating on the tacacs+ server in single-connection mode;
- Fixed an error indicating an incorrect port in the logs when receiving TC BPDU;
- Improved stability of the SSH server;
- Fixed the error of long Port-Channel transition to the Forwarding state when the portfast spanning-tree is configured on it;
- Improved VPC stability;
- Fixed incorrect operation of the BFD via the Port-Channel interface.
Previous versions
Firmware Version 6.6.5.4
Added:
- Ability to configure OOB interface as a source-interface for SNMPv2;
- Ability to configure OOB interface as a source-interface for SNMPv3;
- SNMPv2 support in VRF;
- SNMPv3 support in VRF;
- GRE tunnel support;
- Support for multihomed connections for EVPN/VxLAN scenario with Ingress Replication.
Fixed:
- Improved stability of peer-detection functionality in VPC;
- Erroneous removal of voice vlan from interface by timeout in the presence of port security settings;
- SSH session hangs due to an error in calculating Message authentication code in SSH packet.
Firmware Version 6.6.5
Added:
- Added support for BGP Route Map, Community List and AS-Path List in VRF;
- Added BFD support for BGP in VRF;
- Added BFD support for OSPF in VRF;
- Added support for encryption of the user's password using the SHA512/md5 algorithm;
- Added BFD support for IS-IS;
- Added the ability to change the ipv4 gateway address in EVPN type 5 routes;
- Added support for the RADIUS client in VRF;
- Added the ability to configure the source-interface OOB for SYSLOG;
- Added the ability to configure the OOB source-interface for TACACS+;
- Added BFD support for OSPF;
- Added support for VCT cable diagnostics for SFP-T;
- Added support for an extended number of UDBs in the ACL;
- Increased the number of ACEs in ACL to 512;
- Added support for filtering routes by the value of the as-path attribute in BGP;
- Added community support in BGP;
- Added the ability to configure the source-interface OOB for SNTP;
- Added support for SNTP operation in VRF;
- Added support for SYSLOG operation in VRF;
- Added support for the TACACS+ client in VRF;
- Added support for SSH server operation in VRF;
- Added ARP suppression support for EVPN/VXLAN.
Fixed:
- Fixed the process of removing the VRF setting from the OOB interface;
- Fixed the behavior in which STP root BPDU packets did not pass through the VPC peer-link;
- Fixed a reboot that occurred when the number of ACL rules with port-range was exceeded;
- Fixed L3VNI collaboration with VXLAN in multicast replication mode;
- Fixed incorrect operation of PBR with VRRP;
- Fixed device freeze when configuring SNMPv3;
- Fixed a behavior where a MAC-flapping storm started in a VPC;
- Fixed incorrect isolation of VPC groups from peer-link;
- Fixed a issue with OSPF neighbours breaking when CPU utilisation is high;
- Fixed issue with sending BGP update EVPN Type-2 when MAC address re-learning in a different ethernet-segment;
- Fixed issue with traffic switching via VRRP backup;
- Fixed problem with parasitic ICMP Redirect from VRRP backup when pinging a VRRP IP;
- Fixed a critical error occurring when CPU utilisation is high;
- Fixed critical error occurring when adding OUI for VOICE VLAN;
- Fixed critical error occurring when configuring sflow in stack;
- Fixed a critical error occurring when stack links are broken;
- Fixed critical errors occurring when building STP tree or VPC neighborhoods;
- Fixed L3VNI collaboration with VXLAN in multicast replication mode;
- Fixed PBR collaboration with VRRP;
- Fixed device freeze when removing ACL;
- Fixed device reboot related to the operation of the BGP protocol;
- Fixed device reboot when adding ACLs with UDP and TCP port ranges to the interface;
- Fixed device reboot when deleting VLAN bound to VXLAN;
- Fixed mac flapping between LAG when using VPC;
- Fixed incorrect addition of outgoing VRRPv2 protocol packets;
- Fixed a behavior in which STP root BPDU packets did not pass through the VPC peer-link.
Firmware Version 6.6.4
Added:
- The bit depth of the uptime counter has been increased;
- Added support for macro operation based on track status;
- Added support for cable diagnostics for MES2300-xx/MES3300-xx series devices;
- Added support for displaying information about QSFP28 in the output of the show inventory command;
- Added support for J9285D DAC cables;
- Added VRRP support to VRF;
- Added support for tftp in VRF;
- Added VRF support for the OOB interface;
- Added the ability to disable sending an empty packet to check the availability of the TFTP server;
- Added route-map support for OSPF;
- Added support for policy base routing next-hop;
- Added the ability to summarize routes in BGP;
- The value of the upper limit for the rate-limit has been increased;
- Added the ability to redistribute routes from eBGP to L3VPN;
- Added support for password encryption when logging commands;
- Added the possibility of simultaneous operation of MAC and IP access lists on interfaces;
- Added the ability to check the source mac address in the IP source-guard;
- Added the ability to limit the number of DHCP clients per port;
- Added the ability to send an snmp trap to the login/logout event.
Fixed:
- Software flow control is disabled for the console port;
- Fixed vulnerability of the Web interface;
- The position of the AAA command block in the configuration has been changed;
- Fixed the operation of the DHCP server when sending DHCP NAK packets;
- The operation of optical and copper switches in the same stack has been restored;
- Fixed an error that causes a cyclical reboot of a Slave unit in the stack when upgrading to version 6.6.3.8;
- Fixed rebooting of switches in the scheme with VxVLAN/EVPN when restarting the ospf process;
- Fixed single-hop BFD for eBGP neighborhoods;
- Fixed the problem of routing traffic between stack units for 2300/3300 devices;
- Fixed an error that caused the device to reboot when adding a non-existent VPC domain to the VPC group;
- Fixed an error that causes the role to be retransmitted after the Primary device is rebooted in the VPC;
- Fixed the problem of device freezing when flapping MLAG links in VPC;
- Fixed the problem of incorrect VPC assembly after restarting one of the paired devices;
- Fixed a cyclic reboot of the device when there is an ethertype switchport dot1q setting on the interface;
- Fixed an error in restoring the switchport default-vlan tagged command when updating software;
- Fixed an error where the L3 interface of the physical port did not switch to the Up state when rapid-pvst was enabled;
- Fixed the problem of blocking MLAG, after restarting it, in RPVST;
- Changed the default value of the spanning-tree cost parameter for 25G/40G/100G ports;
- Fixed spanning-tree cost calculation for port-channel interfaces;
- Fixed device reboot when polling the dot1dTpFdbEntry SNMP table;
- Fixed an error that occurs when deleting the SNMPv3 server settings from the configuration;
- Fixed an error when binding the ACL to the interface vlan.
Added:
- FEC operation support for 25G ports.
Fixed:
- Fixed switching part of the links to the UP status when using the FH-DP4T26QS05 40G QSFP/4 SFP+ Fang Zhang Copper Twinax Cable 5M cable.