Ru En
Designer and manufacturer of communication equipment
Russia (GMT +7)

Ethernet Aggregation Switches MES3348F

Mass production
Key features
  • High performance
  • Stacking up to 8 devices
  • 4x10G ports in base configuration
  • Hot-swappable redundant power supplies
  • Advanced L2 functions
  • L3 functions
  • Front-to-Back cooling
MES3348F switches can be used in service provider network as the aggregation or transport switches, as well as in data centers as Top-of-Rack switches. They have a high performance with interfaces operating at speeds of 10 Gbps or 1 Gbps.

The features’ set of  MES3348F includes advanced L2 functions, static routing, dynamic routing, 4 SFP+ 10 Gbps  interfaces, stack up to 8 devices, redundant and hot swappable power supplies. 

Ethernet Ring Protection Switching (ERPS) protocol  provides fast convergence (less than 200 ms) of the network, that guarantees uninterrupted service.



                                                          Application diagram

mes 3348.png


Specifications
Modules and additional devices
Documents and files
Warranty
Interfaces
  • 48 ports of 1000BASE-X/100BASE-FX (SFP)
  • 4 ports of 10GBASE-R/1000BASE-X (SFP+/SFP)
  • Console port RS-232/RJ-45
Performance
  • Bandwidth - 176 Gbps
  • Throughput for 64 bytes¹ - 130.9 MPPS
  • Buffer memory - 3 Mb
  • RAM (DDR3) - 512 MB
  • ROM (RAW NAND) - 512 MB
  • MAC table - 16384
  • ARP table2 - 4023
  • VLAN table - 4094
  • L2 Multicast groups - 4091
  • Number of SQinQ - 3006 (ingress/egress)
  • Number of ACL rules  - 3006
  • L3 IPv4 Unicast routes3 - 12866
  • L3 IPv6 Unicastroutes3 - 3222
  • L3 IPv4 Multicast routes (IGMP Proxy, PIM) - 3876
  • L3 IPv6 Multicast routes (IGMP Proxy, PIM) - 1006
  • VRRP routers - 255
  • Maximum size of ECMP groups - 8
  • VRF - 16 (including default VRF)
  • L3 interfaces - 2048
  • Link Aggragation Groups (LAG) - 48, up to 8 ports per LAG
  • Quality of Service (QoS) - 8 egress queues per port
  • Jumbo frames size - 10240 bytes
  • Stacking - 8 devices
Interfaces functions
  • Head-of-line blocking (HOL) protection
  • Back Pressure 
  • Auto MDI/MDIX 
  • Jumbo frames 
  • Flow control (IEEE 802.3X)
  • Port mirroring (SPAN, RSPAN)
MAC table functions 
  • Independent learning mode per VLAN
  • MAC Multicast Support
  • Configurable aging time of MAC addresses
  • Static MAC Entries
  • MAC Flapping logging
VLAN functions
  • Voice VLAN
  • 802.1Q 
  • Q-in-Q
  • Selective Q-in-Q
  • GVRP
L2 Multicast functions
  • Multicast profiles
  • Static Multicast groups
  • IGMP Snooping v1,2,3
  • Port/host-based IGMP Snooping Fast Leave
  • Pim-Snooping
  • IGMP proxy-report
  • IGMP authorization via RADIUS
  • MLD Snooping v1,2
  • IGMP Querier
  • MVR
L2 functions
  • STP (Spanning Tree Protocol, IEEE 802.1d) 
  • RSTP (Rapid Spanning Tree Protocol, IEEE 802.1w) 
  • MSTP (Multiple Spanning Tree Protocol, IEEE 802.1s) 
  • STP Multiprocess
  • PVSTP+
  • RVSTP+
  • Spanning Tree Fast Link option 
  • STP Root Guard 
  • STP Loop Guard
  • BPDU Filtering 
  • STP BPDU Guard
  • VLAN-based Loopback Detection (LBD)
  • ERPS (G.8032v2)
  • Flex-link
  • Private VLAN
  • Layer 2 Protocol Tunneling (L2TP)
L3 functions
  • Static IP routes
  • Dynamic routing protocols RIPv2, OSPFv2, OSPFv3, IS-IS (IPv4 Unicast), BGP¹ (IPv4 Unicast, IPv4 Multicast, IPv6 Unicast)
  • BFD (for BGP)
  • Address Resolution Protocol (ARP)
  • Proxy ARP
  • Policy-based routing (IPv4)
  • VRRP
  • PIM SM, PIM DM, IGMP Proxy, MDSP
  • IP Unnumbered
  • ECMP Load Balancing
  • GRE
  • VRF
Link Aggregation functions
  • Static LAG
  • Dynamic LAG (LACP)
  • LAG Balancing Algorithm
  • Multi-switch Link Aggregation Group (MLAG)
IPv6 functions
  • IPv6 Host 
  • Dual-stack
Service functions
  • Virtual Cable Testing (VCT)
  • Optical transceiver diagnostics
  • Green Ethernet
Security functions
  • Protection against unauthorized DHCP servers (DHCP Snooping)
  • DHCP Option 82
  • IP Source Guard
  • Dynamic ARP Inspection
  • First Hop Security
  • sFlow
  • MAC-based authentication, Port Security, Static MAC entries
  • Port-based authentication IEEE 802.1x
  • Guest VLAN
  • DoS attack prevention
  • Traffic segmentation
  • DHCP clients filtering
  • BPDU attacks prevention
  • NetBIOS/NetBEUI filtering
  • PPPoE Intermediate Agent
ACL
  • L2-L3-L4 ACL 
  • Time-Based ACL
  • IPv6 ACL
  • ACL based on:
    • Physical port number
    • IEEE 802.1p
    • VLAN ID
    • EtherType
    • DSCP
    • Protocol type
    • TCP/UDP port number
    • User Defined Bytes
Quality of service (QoS) and rate limiting
  • QoS statistics
  • Shaping, Policing
  • IEEE 802.1p Class of Service (CoS)
  • Storm Control for different types of traffic (broadcast, multicast, unknown unicast)
  • Bandwidth management
  • Scheduling algorithms: Strict Priority/Weighted Round Robin (WRR)
  • Three marking colors
  • ACL-based CoS/DSCP mark assignment
  • ACL-based VLAN assignment
  • Setting the IEEE 802.1p priority for management VLAN
  • DSCP to CoS/CoS to DSCP remarking
  • 802.1p, DSCP mark assignment for IGMP
ОАМ/CFM
  • IEEE 802.3ah Ethernet Link OAM
  • Dying Gasp
  • IEEE 802.1ag Connectivity Fault Management (CFM)
  • IEEE 802.3ah Unidirectional Link Detection 
Management functions
  • Download and upload of configuration file via TFTP/SCP
  • Redirecting the output of CLI commands to an arbitrary file on ROM
  • SNMP 
  • Command Line Interface (CLI)
  • Web interface
  • Syslog
  • SNTP (Simple Network Time Protocol)
  • NTP (Network Time Protocol)
  • Traceroute
  • LLDP (802.1ab) + LLDP MED
  • Processing traffic management with two 802.1Q headers
  • Authorization of entered commands using TACACS+ server
  • Access control – privilege levels
  • Management interface blocking
  • Local authentication
  • IP addresses filtering for SNMP
  • RADIUS and TACACS+ (Terminal Access Controller Access Control System) clients
  • Change of Authorization (CoA)
  • SSH server, Telnet server
  • SSH client, Telnet client
  • Remote start of commands via SSH
  • SSL 
  • Macrocommands
  • CLI commands logging
  • System log
  • DHCP autoprovision
  • DHCP Relay (Option 82)
  • DHCP Option 12
  • DHCPv6 Relay, DHCPv6 LDRA (Option 18, 37)
  • PPPoE Circuit-ID tag
  • Debugging commands
  • Rate limit of traffic to CPU
  • Password encryption
  • Password recovery
  • Ping (IPv4/IPv6 support)
  • DNS server (Resolver)
Monitoring functions
  • Statistics on interfaces 
  • RMON/SMON
  • IP SLA
  • CPU utilization monitoring per task and per traffic type
  • Temperature monitoring
  • TCAM utilization monitoring
  • RAM utilization monitoring
MIB
  • RFC 1065, 1066, 1155, 1156, 2578 MIB Structure
  • RFC 1212 Concise MIB Definitions
  • RFC 1213 MIB II
  • RFC 1215 MIB Traps Convention
  • RFC 1493, 4188 Bridge MIB
  • RFC 1157, 2571-2576 SNMP MIB
  • RFC 1901-1908, 3418, 3636, 1442, 2578 SNMPv2 MIB
  • RFC 1271,1757, 2819 RMON MIB
  • RFC 2465 IPv6 MIB
  • RFC 2466 ICMPv6 MIB
  • RFC 2737 Entity MIB
  • RFC 4293 IPv6 SNMP Mgmt Interface MIB
  • Private MIB
  • RFC 3289 DIFFSERV MIB
  • RFC 2021 RMONv2 MIB
  • RFC 1398, 1643, 1650, 2358, 2665, 3635 Ether-like MIB
  • RFC 2668 802.3 MAU MIB
  • RFC 2674, 4363 802.1p MIB
  • RFC 2233, 2863 IF MIB
  • RFC 2618 RADIUS Authentication Client MIB
  • RFC 4022 MIB for TCP
  • RFC 4113 MIB for UDP
  • RFC 3298 MIB for Diffserv
  • RFC 2620 RADIUS Accounting Client MIB
  • RFC 2925 Ping & Traceroute MIB
  • RFC 768 UDP
  • RFC 791 IP
  • RFC 792 ICMPv4
  • RFC 2463, 4443 ICMPv6
  • RFC 4884 Extended ICMP for Multi-Part messages support
  • RFC 793 TCP
  • RFC 2474, 3260 DS field definition in IPv4 and IPv6 headers 
  • RFC 1321, 2284, 2865, 3580, 3748 Extensible Authentication Protocol (EAP)
  • RFC 2571, 2572, 2573, 2574 SNMP
  • RFC 826 ARP
  • RFC 854 Telnet
  • IEC 61850
Technical features
  • Power supply:
    • AC power: 100 - 220V, 50-60 Hz
    • DC power: -36 - 72V
    • Up to 2 hot-swappable DC or AC power supplies
  • Input current:
    • 0.89-0.37 A for AC
    • 2.47-1.24 A for DC
  • Maximum power consumption - 89 W
  • Heat dissipation - 89 W
  • Operating temperature - From -10 to +45 °С
  • Storage temperature - From -50 to +70 °С
  • Operating humidity - no more than 80%
  • Cooling - Front-to-Back, 4 fans
  • Form factor - 19”, 1U
  • Dimensions (WxDxH) - 440х330х44 mm
  • Weight - 4 kg

1 Values are given for 1-way transmission
2 For each host in the ARP table, an entry is created in the routing table
3 IPv4/IPv6 Unicast/Multicast routes share hardware resources

Additional modules (doesn't included in basic package)

PM160-220/12

PM160-220/12 power module, 220V AC, 160W

PM100-48/12

PM100-48/12 power module, 48V DC, 100W

 

 1 fiber

Part Number

 SFP 1.25 GE module, 3 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS3 / FH-SB5312CDS3

 SFP 1.25 GE module, 3 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL3 / FH-SB5312CDL3

 SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS20 / FH-SB5312CDS20

 SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL20 / FH-SB5312CDL20

 SFP 1.25 GE module, 20 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM, INDUSTRIAL

FH-SB3512IDS20 / FH-SB5312IDS20

 SFP 1.25 GE module 40 km, SM, 1 fiber, TX/RX 1310/1550 LC set, DDM

FH-SB3512CDL40 / FH-SB5312CDL40

 SFP 1.25 GE module 40 km, SM, 1 fiber, TX/RX 1310/1550 SC set, DDM

FH-SB3512CDS40 / FH-SB5312CDS40

 SFP 1.25 GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL80 / FH-SB5412CDL80

 SFP 1.25 GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 SC set, DDM

FH-SB4512CDS80 / FH-SB5412CDS80

 SFP 1.25 GE module 120 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL120 / FH-SB5412CDL120

 SFP 1.25 GE module 120 km, SM, 1 fiber, TX/RX 1490/1550 SC set, DDM

FH-SB4512CDS120 / FH-SB5412CDS120

 SFP 1.25 GE module 160 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SB4512CDL160 / FH-SB5412CDL160

 2 fibers

 

 SFP 1.25 GE module 550 m, MM, 2 fibers, 850 nm,  LC,  DDM

FH-S8512CDL05

 SFP 1.25 GE module 2 km, ММ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL2

 SFP 1.25 GE module 20 km, SМ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL20

SFP 1.25 GE module 40 km, SМ, 2 fibers, 1310 nm, LC, DDM

FH-S3112CDL40

 SFP 1.25 GE module 80 km, SМ, 2 fibers, 1550 nm, LC, DDM

FH-S5512CDL80

 SFP 1.25 GE module 120 km, SМ, 2 fibers, 1550 nm, LC, DDM

FH-S5512CDL120

 SFP 1.25 GE module 160 km, SМ, 2 fibers, 1550 nm, LC, DDM   

FH-S5512CDL160

SFP+

 

 1 fiber

 

 SFP+ 10GE module 3 km, SM, 1 fiber, TX/RX 1290/1310 LC set, DDM

FH-SPB311TCDL3 / FH-SPB191TCDL3

 SFP+ 10GE module 20 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL20 / FH-SPB321TCDL20

 SFP+ 10GE module 40 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL40 / FH-SPB321TCDL40

 SFP+ 10GE module 60 km, SM, 1 fiber, TX/RX 1330/1270 LC set, DDM

FH-SPB231TCDL60 / FH-SPB321TCDL60

 SFP+ 10GE module 80 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SPB451TCDL80 / FH-SPB541TCDL80

 SFP+ 10GE module 100 km, SM, 1 fiber, TX/RX 1490/1550 LC set, DDM

FH-SPB451TCDL100 / FH-SPB541TCDL100

 2 fibers

 

 SFP+ 10GE module, 0.3 km, MM, 2 fibers, 850 nm, LC, DDM

FH-SP851TCDL03

 SFP+ 10GE module, 20 km, SM, 2 fibers, 1310 nm, LC, DDM

FH-SP311TCDL20

 SFP+ 10GE module, 40 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL40

 SFP+ 10GE module, 80 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL80

 SFP+ 10GE module, 100 km, SM, 2 fibers, 1550 nm, LC, DDM

FH-SP551TCDL100

SFP/SFP+ transceivers with RJ-45 interface

 

 SFP transceiver of 10/100/1000 BASE-T 

FH-ST2

 SFP+ transceiver of 10GBASE-Т 

FH-10SFP-T

SFP+ Direct Attach Cable 

 

 SFP+ Direct attach cable, 10G, 1m

FH-DP1T30SS01

 SFP+ Direct attach cable, 10G, 2m

FH-DP1T30SS02

SFP+ Direct attach cable, 10G, 3m

FH-DP1T30SS03

SFP+ Direct attach cable, 10G, 5m

FH-DP1T30SS05

Operational lifetime of the ELTEX equipment
In development
1
Pre-production
2
Mass production
3
Mass production is over
4
Sold out
5
Support is over
6
Regardless of the operational lifetime stage, Eltex provides a 12 months warranty on all its telecommunication equipment.
During the warranty period the manufacturer ensures technical support and free-of-charge repair at the Enterprise which is situated in Novosibirsk.
As part of the warranty service, technical support is provided on the first-in first-out principle.
The priority support packages of 8/5 and 27/7 types are subjects to additional charges.

Помогите сделать
сайт лучше